Guide · Exam prep

SPI practice questions: Doppler physics and hemodynamics

Physics and instrumentation are the subject of the SPI exam (ARDMS) and the foundation of the RVT and RPVI exams. These 6 original questions cover the calculations that come up most, each with an explained answer.

Quick answerThe calculations that come up most: the Doppler equation (cos 60° = 0.5), the Nyquist limit (half the PRF), angle error (largest above 60°), continuity (half the diameter, 4 times the velocity), Poiseuille (half the radius, 16 times the resistance) and the 13-µs rule per centimeter.

Where physics is tested

The SPI exam (ARDMS, part of Inteleos) has about 110 questions over 2 hours, on ultrasound physics, instrumentation, safety and quality assurance. In Brazil, “ultrasound and color Doppler fundamentals” is the first of the 11 topics on the 2026 board certification outline (CBR). iDoppler is independent and not affiliated with ARDMS, APCA or Inteleos; these questions are original and not taken from any exam.

Doppler physics

1. Angle and Doppler shift

Flow velocity and transducer stay the same, and the insonation angle changes from 0° to 60°. What happens to the Doppler shift?

Answer: C. In the Doppler equation, Δf = 2·f₀·v·cos θ / c. Because cos 0° = 1 and cos 60° = 0.5, the shift is halved. At 90°, cos θ = 0 and there is no measurable shift.

2. Nyquist limit

With a pulse repetition frequency (PRF) of 4 kHz, what is the highest Doppler shift measured without aliasing?

Answer: B. The Nyquist limit is half the PRF. Above 2 kHz the spectrum wraps around. To fix it: raise the scale, shift the baseline, reduce depth or transducer frequency, or use continuous-wave Doppler.

3. Angle error

The angle cursor is 5° off the vessel axis. At which insonation angle does this produce the largest error in calculated velocity?

Answer: D. Velocity is calculated by dividing by cos θ, and the cosine changes faster at high angles. A 5° error changes velocity by about 5% at 30° and by about 20% to 30% at 70°. That is why measurements are made at an angle of 60° or less.

Hemodynamics and pulse-echo

4. Continuity equation

Flow is constant and the lumen diameter is halved in one segment. How much does velocity increase in that segment?

Answer: B. Flow = area × velocity. Halving the diameter reduces the area to 1/4 (a 75% area reduction), so velocity rises 4 times. In very severe stenoses flow falls and this relationship no longer holds.

5. Resistance and radius

By Poiseuille's law, if a tube's radius is halved and nothing else changes, resistance to flow:

Answer: D. Resistance is proportional to 8ηL / (πr⁴). Halving the radius reduces r⁴ to 1/16, so resistance rises 16 times. Radius matters far more than length or viscosity.

6. Round-trip time

In soft tissue (1,540 m/s), an echo returns to the transducer 65 µs after the pulse. How deep is the reflector?

Answer: B. The 13-microsecond rule: in soft tissue, each centimeter of depth takes about 13 µs round trip. 65 ÷ 13 = 5 cm.

Formula sheet: the 6 calculations at a glance

ConceptFormula or ruleWhat to remember
Doppler equationΔf = 2·f₀·v·cos θ / ccos 0° = 1, cos 60° = 0.5, cos 90° = 0: no shift at 90°
Nyquist limitNyquist = PRF ÷ 2PRF 4 kHz → aliasing above 2 kHz
Angle errorv = Δf·c / (2·f₀·cos θ)Measure at 60° or less; error grows fast above 60°
ContinuityFlow = area × velocityHalf the diameter → 1/4 the area → 4 times the velocity
PoiseuilleR = 8ηL / (πr⁴)Half the radius → 16 times the resistance
13-µs ruleDepth (cm) = round-trip time (µs) ÷ 1365 µs → 5 cm in soft tissue (1,540 m/s)
Summary of the six questions above.

Practice with explained questions

The free iDoppler account includes sample lessons and sample questions with an explanation for every option. The full course with the complete question bank (1,500+ original questions) opens in early 2027. No course can guarantee a result. Not affiliated with ARDMS or APCA.

Start free

Frequently asked questions

What does the SPI exam cover?

Ultrasound physics and instrumentation, including clinical safety, quality assurance, transducers, image optimization and Doppler concepts: about 110 questions over 2 hours, according to Inteleos, the parent organization of ARDMS.

Why measure velocity at an angle of 60° or less?

Because the calculation divides by cos θ, and above 60° a small cursor error produces a large velocity error: about 20% to 30% for a 5° error at 70°, versus about 5% at 30°.

What is the 13-microsecond rule?

In soft tissue, with an average speed of 1,540 m/s, a pulse takes about 13 µs to travel to and from each centimeter of depth. The system uses this time to place the echo on the image.

What is the Nyquist limit?

It is half the pulse repetition frequency (PRF). A Doppler shift above it is sampled too slowly and wraps around to the other side of the baseline (aliasing). Example: with a PRF of 4 kHz, the Nyquist limit is 2 kHz.

Does shifting the baseline raise the Nyquist limit?

No. The Nyquist limit stays at PRF/2. Moving the baseline only gives more of the display to one flow direction, which can unwrap a signal that flows in a single direction. To raise the limit itself, increase the PRF (scale), which a shallower sample volume allows; a lower transducer frequency reduces the Doppler shift instead.

References

  1. Kremkau FW. Sonography Principles and Instruments. 9th ed. St. Louis: Elsevier; 2016.
  2. Pellerito JS, Polak JF. Introduction to Vascular Ultrasonography. 7th ed. Philadelphia: Elsevier; 2020.
  3. Colégio Brasileiro de Radiologia e Diagnóstico por Imagem. Edital nº 1855 — Certificado de Área de Atuação em Ecografia Vascular com Doppler 2026 (normativa). link
  4. Inteleos/ARDMS. Sonography Principles and Instrumentation (SPI) examination. link
Dr. Vinicius Cruz MajdalaniVascular surgeon · RVT, RPVIVascular surgeon and vascular sonographer (RVT, RPVI), creator of iDoppler. Reviewed on 11/24/2026.